{"id":1310,"date":"2017-06-04T19:47:14","date_gmt":"2017-06-04T11:47:14","guid":{"rendered":"http:\/\/www.wemacro.net\/?product=micromate"},"modified":"2026-01-12T13:23:10","modified_gmt":"2026-01-12T05:23:10","slug":"micromate","status":"publish","type":"product","link":"https:\/\/www.wemacro.com\/?product=micromate","title":{"rendered":"MicroMate"},"content":{"rendered":"<ul>\n<li>We recommend using the WeMacro 5.0 control program, which allows you to directly calculate the step size of the objective lens. When Micromate is selected in the program, the actual working step size on the microscope will be displayed.It\u00a0 can be downloaded <a href=\"https:\/\/www.wemacro.com\/?p=509\" target=\"_blank\" rel=\"noopener\">here<\/a>.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1421\" src=\"http:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/mm-working-1.jpg\" alt=\"\" width=\"800\" height=\"533\" srcset=\"https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/mm-working-1.jpg 1200w, https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/mm-working-1-600x400.jpg 600w, https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/mm-working-1-300x200.jpg 300w, https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/mm-working-1-768x512.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>MicroMate is specially designed for microscope focus stacking.The motor on MicroMate is 400 step 0.9 degree.<\/p>\n<p><strong>Please note that this device is not suitable for use with stereo microscopes.<\/strong><\/p>\n<p>For a clear display effect, we enlarged the step size, and each click sound represents taking a photo. The current version of the control box has a silent shutter.<\/p>\n<div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-1310-1\" width=\"640\" height=\"480\" poster=\"https:\/\/www.wemacro.com\/wp-content\/uploads\/2024\/01\/micromate-knob-mp4-image.jpg\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/07\/micromate-knob.mp4?_=1\" \/><a href=\"https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/07\/micromate-knob.mp4\">https:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/07\/micromate-knob.mp4<\/a><\/video><\/div>\n<p>The hight of motor can be adjusted as 2cm-18cm(It depends on the fine adjustment knob height)The knob\u2019s diameter should smaller than 5 cm.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1418\" src=\"http:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/Micromate.gif\" alt=\"\" width=\"600\" height=\"400\" \/><\/p>\n<p><strong>The package contain \u00a0as below:<\/strong><\/p>\n<p>1,\u00a0MicroMate\u00a0 bracket<\/p>\n<p>2,Control box(bluetooth build-in)<\/p>\n<p>3,Power supply (12V2A,Please select your contry&#8217;s type)<\/p>\n<p>4,USB cable(about 1.5m)<\/p>\n<p>5,Stepper motor cable( about 1m)<\/p>\n<p>6, Shutter extension cable(about 1.5m)<\/p>\n<p>7, Shutter release cable (Please select in option)<\/p>\n<p>8,Reverse motor cable(It&#8217;s better to let objective lens leave the sample in stacking)<\/p>\n<p>If the fine adjust focus of microscope rotate one circle as 200 micron.<span data-slate-fragment=\"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\">This means that if the software is set to 10 micrometers per step, the actual movement will be 1 micrometer per step.<\/span><\/p>\n<p>The actual step size is exactly one tenth of the input value in the software.<\/p>\n<p>When the fine-tuning knob of the microscope is set to 100 micrometers per turn, the relationship becomes 20 times, meaning that a step length of 20 micrometers in the software corresponds to 1 micrometer of actual movement.<\/p>\n<p><a href=\"https:\/\/drive.google.com\/file\/d\/1dA1_CUNhkFbtqdlxYGvZhRPL9oFHa3aH\/view?usp=sharing\" target=\"_blank\" rel=\"noopener\">Manual download<\/a><\/p>\n<p>Shutter release cable type<\/p>\n<p><strong>1C<\/strong> \u00a0For \u00a0<strong>Canon<\/strong>\u00a0EOS1100D(Rebel T3), 700D(T5i), 650D(T4i), 600D(T3i),60Da, 60D,70D, 550D(T2i), 500D (Digital Rebel T1i), 1000D (Digital Rebel XS), 450D (Digital Rebel XSi ), 400D (Digital Rebel XTi ), 350D (Digital Rebel XT), 300D (Digital Rebel), Canon EOS 30, 33, 50, 50E, 300V, 300, 3000\u2026etc;<br \/>\nPowershotG15,G12,G11,G10,G1X;<br \/>\nPENTAX<em>\u00a0<\/em>K-7,K-X,K-50,K-1,645,etc<\/p>\n<p><strong>3C<\/strong> For\u00a0<strong>Canon<\/strong>:EOS6D, 7D, 50D, 40D, 30D, 5D, 20D, 10D, 5D Mark II, 5D Mark III, 1D X, 1D Mark IV,1Ds Mark III, 1D Mark III, 1D Mark II N, 1Ds Mark II, 1D Mark II.<\/p>\n<p><strong>1N<\/strong> For <strong>Nikon<\/strong>\u00a0D4, D3X, D3,\u00a0D700, D800, D800E, D700, D300S, D300, D200;D810;D500<\/p>\n<p><strong>3N<\/strong> For <strong>Nikon<\/strong>:D600, D3200, D3100, D5100, D7000, D7100,D7200, D5000, D90,D750<\/p>\n<p><strong>J<\/strong> for\u00a0<strong>Olympus<\/strong> E-620,E-600,E-550,E-520,E-450,E-420,E410,E-100,E-30,E-PM1,E-M5,E-PL2,E-PL3,E-P3,EP-2,EP-1,SP-590UZ,570UZ,565UZ,560UZ,550UZ,510UZ,810UZ,SZ-30MR,SZ-20,SZ-11<br \/>\n<strong>S2<\/strong> for<strong> Sony<\/strong> :A58 NEX-3NL A7 A7R A7R2 A7S A3000 A5000 A6000 HX300 HX50V RX100II RX100III<\/p>\n<p><strong>E3 \u00a0<\/strong>for <strong>Fuji\u00a0<\/strong>X-Pro2,X-E2S,X70,X-T10,X30\uff0cX100T\uff0cX-T1\uff0cX-E2\uff0cFinePixS1,X-M1,X-A1,XQ1,X-A2,XQ2<\/p>\n<p><strong>S1<\/strong> for\u00a0<strong>Sony<\/strong>\uff1aA900 A700 A850 A550 A500 A450 A400 A350 A300 a200,a100,a99\u3001a77\u3001a65\u3001a57\u3001a55\u3001a35\u3001a33<\/p>\n<p><strong>L1<\/strong> for <strong>Panasonic\uff1a<\/strong>DMC-FZ50, DMC-FZ50K, DMC-FZ50S, DMC-FZ30, DMC-<br \/>\nFZ30K, DMC-FZ30S, DMC-FZ20, DMC-FZ20K, DMC-FZ20S,LC-1,L1.G1 GH1 GF1 GH2 G3 GH3 GH4 GX7<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>By using this formula<\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2388\" src=\"http:\/\/www.wemacro.com\/wp-content\/uploads\/2017\/06\/DOF-f.jpg\" alt=\"\" width=\"217\" height=\"139\" \/><\/li>\n<li>reference \u00a0 \u00a0DOF \uff08<strong>4X<\/strong> INFINITY PLAN OBJECTIVE LENS in our shop\uff09 = 55 \u03bcm<\/li>\n<li>reference \u00a0 \u00a0DOF \uff08<strong>10X<\/strong> INFINITY PLAN OBJECTIVE LENS in our shop\uff09 = 8.8 \u03bcm<\/li>\n<\/ul>\n<p>There is other formula to calculate DOF,Please visit the link for more information.(<a href=\"https:\/\/www.microscopyu.com\/microscopy-basics\/depth-of-field-and-depth-of-focus\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.microscopyu.com\/microscopy-basics\/depth-of-field-and-depth-of-focus<\/a>)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>We recommend using the WeMacro 5.0 control program, which allows you to directly calculate the step size of the objective lens. When Micromate is selected in the program, the actual working step size on the microscope will be displayed.It\u00a0 can be downloaded here. &nbsp; MicroMate is specially designed for microscope focus stacking.The motor on MicroMate [&hellip;]<\/p>\n","protected":false},"featured_media":8695,"template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1310","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-extreme-macro","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-variable"},"_links":{"self":[{"href":"https:\/\/www.wemacro.com\/index.php?rest_route=\/wp\/v2\/product\/1310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wemacro.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wemacro.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wemacro.com\/index.php?rest_route=\/wp\/v2\/media\/8695"}],"wp:attachment":[{"href":"https:\/\/www.wemacro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1310"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wemacro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=1310"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wemacro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1310"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wemacro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}